Business Details: Asian Industrial Valves and Instruments (ASVIN) are one of the leading industries manufacturing Valves and Instruments for Process industries like Chemical, Petroleum, Refineries, Fertilizers, Nuclear, Atomic, Paper, Sugar, Drugs and Pharma, Steel, Cement and other allied industries. ASVIN made a big start with small set up in 1983 and have progressed so confidently. Today ASVIN are one of the well known Organizations in valve manufacturing industry. The broad categories of products manufactured by us include Level Gauges (Reflex, Tubular & Transparent), Level Indicator (Float & Chord, Magnetic), Level switch, Sight Flow Indicator, Ball Valve, Needle valve, Safety valve, Strainer, Cut Gasket, Orifice Plate Assembly, Condensing Pot and Manifold. The broad categories of products manufactured by us include Level Gauges (Reflex, Tubular & Transparent), Level Indicator (Float & Chord, Magnetic), Level switch, Sight Flow Indicator, Ball Valve, Needle valve, Safety valve, Strainer, Cut Gasket, Orifice Plate Assembly, Condensing Pot and Manifold. ASVIN have over 500 customers which include giant organizations like Department of Atomic Energy, Nuclear Power Corporation, Department of Space, Bharat Heavy Electricals Ltd., Bharat Heavy Plates and Vessels Ltd., Hindustan Petroleum Corporation Ltd., Indian Oil Corporation Ltd, Bharat Petroleum Corporation Ltd, Oil and Natural Gas Corporation Ltd, Hindustan Shipyard Ltd., The Fertilizers & Chemicals Travancore Ltd , Neyveli Lignite Corporation Ltd., etc. ASVIN are also approved by various leading consultants /inspection agencies such as Bureau Veritas, Indian Register of Shipping, Lloyds Register of shipping , Dalal Consultants & Engineers Ltd, Industrial Consulting Bureau, FACT Engineering and design organization, Tata Consulting Engineers, Protech Consultants Pvt.Ltd, Avant Garde Engineers and Consultants, IBR, RITES, Superintendence Company of India Ltd., Bax Council , Nuclear Power Corporation of India Ltd., Chief Controller of Explosives , SGS India Ltd, DNV and Ram Safety Systems. ASVIN have a full fledged quality control department with qualified quality control engineers who maintain Quality Management System.

Business Type: Manufacturing

Keywords: SAFETY VALVES, PRESSURE RELIEF VALVES, THERMAL RELIEF VALVE, REPTURE DISC, ATMOSPHERIC CONDENSER RELIEF VALVE

Office Location: Tamil Nadu

EXCESS FLOW CHECK VALVES
  • Category: Petroleum and Products
  • Keywords: Excess Flow Check Valves are normally open valves. They are to be positioned in the tank line or tank fitting so that high velocity of flow outward from the tank will force the valves to the closed position. Each valve design is rated for one particular maximum rate of flow. It will allow the passage of any rate of flow less than, and up to and including, this maximum flow rate. With an increase of velocity of flow, the valve will remain closed as long as this differential prevails. *It is evident that, if the valve is properly installed and the piping and fittings are properly sized for the installation, the valve automatically will close in case of breakage of the line or any fitting in the flow system on the side of the valve away from the tank unless the pressure in the tank is too low to maintain valve-closing velocity through the broken line. When repairs to the system are made and pressure closed in, the slight see page through the small orifice in the excess flow check valve head will, in time, allow pressures to equalize on both sides of the excess flow check valve and the excess flow check valve again will open to flow position and will be ready for further use. Flow lines should be as short and as free from bends and other flow restrictions as possible. Lines and fittings should not be reduced to smaller size than the size of the line for which the valve is intended as indicated by the last size code letter in the valve number. Excess Flow Check Valves are normally open valves. They are to be positioned in the tank line or tank fitting so that high velocity of flow outward from the tank will force the valves to the closed position. Each valve design is rated for one particular maximum rate of flow. It will allow the passage of any rate of flow less than, and up to and including, this maximum flow rate. With an increase of velocity of flow, the valve will remain closed as long as this differential prevails. *It is evident that, if the valve is properly installed and the piping and fittings are properly sized for the installation, the valve automatically will close in case of breakage of the line or any fitting in the flow system on the side of the valve away from the tank unless the pressure in the tank is too low to maintain valve-closing velocity through the broken line. When repairs to the system are made and pressure closed in, the slight see page through the small orifice in the excess flow check valve head will, in time, allow pressures to equalize on both sides of the excess flow check valve and the excess flow check valve again will open to flow position and will be ready for further use. Flow lines should be as short and as free from bends and other flow restrictions as possible. Lines and fittings should not be reduced to smaller size than the size of the line for which the valve is intended as indicated by the last size code letter in the valve number.
  • Manufacturer Name:
  • Packing size:
  • Price: ₹30,000

Description

EXCESS FLOW CHECK VALVES are safety mechanisms. They are to be installed in flow lines to and from pressure tanks, as near to the tank as possible. Their purpose is to shut off the flow of fluid from the tank in case of breakage or rupture of any flow line or fitting located on the outlet side of the valve.