home Advertise
With Us

88XXXXXX43

Send Message

Contact Detail

Veersun Global Enterprise

Street Address: 360, VEERSUN GLOBAL ENTERPRISE, MULLAI, 360, MIG, THANJAVUR

City: THANJAVUR

Province/State: Tamil Nadu

Country: India

Additional Information

Business Details: Government & Corporate supplies

Business Type: Services

Keywords: Sanitary Napkin Incinerator, Disinfection wipes, Baby Wipes, FMCG Products, Food & Non Food Items

Office Location: Tamil Nadu

Sanitary Napkins Incinetator Machine with Smoke Control Unit
  • Model No: RI-104V
  • Category: C Distributor and Dealer
  • Keywords: Incinerator Machine, sanitary, smoke control
  • Manufacturer Name:
  • Packing size: NA
  • Price: ₹45,999

Description

GENERAL Type Floor Mountable Purpose Burn used Sanitary Napkins to sterile ash and stop automatically Color Pink Operation Mode Electronically operated, fully Automatic Loading Type Front loading Stand provided Yes Number of chambers Two Trap Door available Yes All MS parts Powder coated Yes Spare parts should be available for Minimum 5 years from date of supply Yes All electrical parts are ISI Marked Yes DIMENSIONS OF MAIN UNIT Thickness of thermal Insulation material (mm) 40 millimeter Thickness of MS/SS sheet of housing cabinet (external) (mm) 1.2 millimeter Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) 5 millimeter Machine Width(mm) 301-400 Machine Depth (mm) 201-300 Machine Hight(mm) 501-700 Machine Weight(kg) 5-15 Door width(mm) 500-100 Door height(mm) 50-100 Thickness of door including insulation (mm) 40 millimeter Internal/burning chamber shape Vertical cylindrical Flexible emission Outlet pipe dia (mm) 40 millimeter Detachable ash tray length (mm) 100-150 Detachable ash tray width (mm) 100-150 Detachable ash tray height (mm) 5-15 Stand Height (mm) 500 millimeter Stand Width (mm) 301-400 Stand Depth (mm) 201-300 MATERIAL OF MACHINE UNIT Material of Housing cabinet (External) Mild Steel(CRCA) sheet Material of Burning chamber (Internal) Mild Steel(CRCA) sheet Finish of MS parts of cabinet Epoxy anti rust proof painting for superior finish Material of Thermal Insulation High Density Ceramic Board CONSTRUCTIONAL FEATURES Thermal insulation of burning chamber housed in outer chamber Yes Burning Chamber tray provided Yes Emission Outlet pipe location Top of machine Means of connecting the unit outlet with flue gas emission pipe Flanged Type of door lock provided Latch lock CONTROL & FUNCTIONAL FEATURES Temperature indicator provided Yes Timer provided Yes Auto cut-off temperature display Yes Digital display to see actual and set temperature Yes Minimum Burning temperature (degree C) 800 Burning Capacity per day (Number of Napkins) 51-100 Burning Capacity at a time (Number of Napkins) 1-15 Residue Ash per Napkin (gms) 1 gram Burning time of full capacity Napkins/pads (minutes) (Max) 10 minute Skin temperature of the unit under operation (deg C) 0-15 Installation, training, demonstration and plumbing included Yes ELECTRICAL AND SAFETY FEATURES Automatic digital controller for time Yes Automatic digital controller for temperature Yes Equipment ON/OFF indicator provided Yes Power supply 230v +/-10%, 50Hz, Single phase, AC supply Electrical Power Consumption(Watt) 500-1000 Minimum length of power chord to be supplied along with machine (mtr) 2 meter Type of Heater Ceramic heater containing coil Power saver (auto power cut-off) Yes Safety MCB provided (16A to 30A) Yes Protection against electric shock when checked as per IS:302-1/2008 Yes Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) 2 Maximum Electrical Insulation and Leakage current as per IS:302-1/2008, (mA) 0.21 Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) 0.1 HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 No breakdown shall occur during the test SMOKE CONTROL UNIT (SCU) Type of SCU (Smoke Control Unit) Top mounted Material of housing of Smoke Control Unit (SCU) Mild Steel(CRCA) cabinet Finish of MS parts of SCU cabinet Epoxy anti rust proof painting for superior finish Overall height of SCU (mm) 0 Overall width of SCU (mm) 301-500 Overall depth of SCU (mm) 301-500 Number of chambers for filteration of smoke emission Two Both carbon Control and Foul odour Control Chambers for filteration of smoke emission Yes Number of filters in Carbon control chamber Two Type of filters in Carbon control chamber Activated Carbon filter Number of filters in Odour control chamber Two Type of filters in Odour control chamber Activated Carbon filter Blower type NA Blower RPM 1800 Power supply of SCU 230v +/-10%, 50Hz, Single phase, AC supply Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) 3 Cost of additional flexible emission outlet pipe, if required on actuals to be paid by the user Yes EMISSION STANDARD FOR SMOKE Conformity to CPCB, Min of Environment & Forests standard, Solid Waste Management Rules (SWM), 2016 Yes Particulates (Half hourly average) (mg/Nm3) (Max) 50 HCl (Half hourly average) (mg/Nm3) (Max) 50 SO2 (Half hourly average) (mg/Nm3) (max) 200 CO (Half hourly average) (mg/Nm3) (Max) 100 CO (Daily average) (mg/Nm3) (Max) 50 Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) 20 HF (Half hourly average) (mg/Nm3) (Max) 4 "Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" 400 Total dioxins and furans ( 6 to 8 hours sampling basis, Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) 0.1 Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.5 Loss on ignition (max) (% dry weight of the material) 5 PACKING Packing Carton Box MARKING AND INSTRUCTIONS The appliance is marked as per IS:302-1/2008 Yes CERTIFICATION Submission of Test Report from Central Govt/CSIR Lab/NABL/ILAC accredited Lab specifically containing Electrical & Electronic parameters,Thermal insulation material of burning chamber in addition to declared specification parameter at time of supply Yes Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollution Control Board (CPCB) norms from NABL accredited lab/CSIR Lab at the time of supply Yes Certification Available EU-CE,BIS,US-FDA,Other,CSIR-NEERI Certificate for Manufacturing premises available ISO Compliance certificate is to be furnished after conducting comprehensive performance test by the supplier Yes Submission of all the certifications to the buyer along with supplies Yes