home Advertise
With Us
  • Download Download pdf,docx,csv,xls File

    FULLY AUTOMATIC OXYGEN CONTROL PANEL India

    19 Aug 2021

    Requirement Description: Oxygen Supply System SITC of fully automatic control panel with minimum flow rate of 1500LPM with 2 x 12 cylinder manifold complete with tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard EN ISO7396-1. 1 set N2O Supply system SITC of fully automatic control panel with minimum flow rate of 500 LPM with 2x6 cylinder manifold complete with tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard EN ISO7396-1. 1 ...

    Quantity: 1

    Order Value: 20001 to 50000

    Buying Need: Immediate

     

  • Product Basic information

    Product Name: FULLY AUTOMATIC OXYGEN CONTROL PANEL
    Category Name: HEALTH AND BEAUTY
    Sub Category: Health Equipment
    Requirement Description: Oxygen Supply System SITC of fully automatic control panel with minimum flow rate of 1500LPM with 2 x 12 cylinder manifold complete with tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard EN ISO7396-1. 1 set N2O Supply system SITC of fully automatic control panel with minimum flow rate of 500 LPM with 2x6 cylinder manifold complete with tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard EN ISO7396-1. 1 set SITC of emergency regulator with minimum flow rate of 500LPM with 1x 3 cylinder manifold complete with tail pipes, NRV, fixing chain etc.The installation must fully comply with the standard EN ISO7396-1. 1 set Duplex Air Compressor Plant Duplex Air Plant must have 3 Piston compressors complete with all required cooling, control and monitoring facilities for operations in system with 1 compressors running & 2 compressors standby, a control panel, 2 air receivers 2200 L., 2 Dryer and filtration unit - 5-stage conditioning systems with filters and adsorption dryer and a pressure reducer station. The installation must fully comply with the standard EN ISO7396-1 and the produced air must be for medical use according to the European Pharmacopoeia as following. Each compressor should have minimum FAD of 2000 LPM . 1 set Dulex Vacuum plant Duplex vacuum Plant must have 3 rotary vane type vacuum pumps directly driven by motor,operations in system with 1 vacuum pumps running & 2 vacuum pumps standby, a control panel, 1 vacuum receivers 1200 Ltr., secretion Trap and bacteria filter. The installation must fully comply with the standard EN ISO7396-1. each vacuum pump should have FAA 2900 LPM- at 450mmHg, 1 set Area alarm + Area valves - Area alarm and shut-off unit for medical gases must be acc. To EN ISO7396-1. Area alarm and area valves should be in a single unit. 1 Gas (O2) and 1 Vac 0 pcs 2 Gases (O2, Air) and 1 Vac 4 pcs 3 Gases (O2, Air) Air and 1 Vac 6 pcs 4 Gases (O2, Air, Air 7, N2O) and 1 Vac 3 pcs
    E-Mail: XXXXXXX@XXXXX.com
    Phone: XXXXXXXXXX
    Quantity: 1
    Quantity Unit: Nos
    Order Currency: INR
    Order Value: 20001 to 50000
    Prefered Location: Anywhere in India
    Location Name: Maharashtra
    Buying Need: Immediate
    Requirement Frequency: Regular
    Date: 2021-08-19 14:30:04.000